Take Note - the low Voltage Output is AC
Lamp wattage: 20…70 W
Line current: 0.30 A
Power factor: 0.95
Operating frequency: 50 kHz
Nominal output voltage: 11.9 / 12.0 V AC
Nominal voltage: 220…240 V AC
Input voltage AC: 198…264 V
Mains frequency: 50…60 Hz
System wattage: 74.00 W
Max. ECG no. on circuit breaker 10 A (B): 37
Max. ECG no. on circuit breaker 16 A (B): 59
ECG efficiency: 95 %
Galvanic isolation primary/secondary: 4.00 kV
Inrush current: 0.45 A
Product features
- Line frequency: 50…60 Hz
- RI suppression: to EN 55015 (A1: 2007)/CISPR 15, EN 55022
- Line harmonics according to EN 61000-3-2
- Immunity according to EN 61547
- Energy efficiency: ≥ 91 % (according to ErP regulation 2012/1194/EC)
- Safety: to EN 61347
- Short-circuit protection, overload protection, overtemperature protection: electronically reversible
- Electrical isolation between the primary side and the secondary side
- Switching between electronic transformer and lamp not permitted
- Dimmable on the leading edge and trailing edge
Compatible with:
Synergi 6W MR16 12V Downlight